ANÁLISIS COMPARATIVO EN DISEÑOS DE HORMIGONES EMPLEANDO FIBRAS DE POLIPROPILENO FIBRILADA Y MICROFILAMENTO FINO CON MATERIALES DE LA CANTERA MEGAROK DE PICOAZA PARA RESISTENCIA DE F¨c 240 kg/cm2

No Thumbnail Available
Authors
Journal Title
Journal ISSN
Volume Title
Tutor
Co-Tutor
Publisher
UNIVERSIDAD TÉCNICA DE MANABÍ.FACULTAD DE CIENCIAS MATEMÁTICAS FÍSICAS Y QUÍMICAS.CARRERA DE INGENIERÍA CIVIL.
Campo Amplio
Campo Espec�fico
Num. P�ginas
Date
2017-10
Abstract
“ANÁLISIS COMPARATIVO EN DISEÑOS DE HORMIGONES EMPLEANDO FIBRAS DE POLIPROPILENO FIBRILADA Y MICROFILAMENTO FINO CON MATERIALES DE LA CANTERA MEGAROK DE PICOAZA PARA RESISTENCIA DE F¨c 240 kg/cm2” La presente investigación tiene como objetivo realizar un análisis comparativo en el diseño de hormigones empleando fibras de polipropileno (fibrilada y microfilamento fino) con los agregados (finos y gruesos) de la cantera Megarok de la Parroquia Picoazá para obtener una resistencia nominal de F”c 240 kg/cm2. Para la construcción de los hormigones, primeramente se determinaron las propiedades físico-mecánicas de los agregados obtenidos, encontrándose que ellos presentan las características correctas encontrándose dentro de los rangos establecidos en la norma INEN 0862. Posterior a ello se determinó las dosificaciones necesarias de los agregados fino (1,90) y grueso (2,32), el cemento (1,00) y de agua (0,51), que componen la estructura del hormigón, estableciéndose que para la masa necesaria para elaborar los 6 hormigones propuestos son 8.023 kg de agua, 15.731 Kg de cemento, 29.825 Kg de arena y 36.420 Kg de ripio. Con los datos obtenidos se elaboraron los 6 cilindros de hormigones, de los cuales, 3 (15 kg c/u, contenían 5 g de fibras) los cuales servirán para desarrollar los ensayos para comprobar que su resistencia a compresión a los 7, 14 y 28 días presentaban los 240 Kg/cm2 requeridos, encontrándose en los resultados que ambos hormigones cumplían con la resistencia nominal requerida. Concluyendo que la utilización de las fibras de polipropileno agregada no influyen en la resistencia del hormigón final.
“ANÁLISIS COMPARATIVO EN DISEÑOS DE HORMIGONES EMPLEANDO FIBRAS DE POLIPROPILENO FIBRILADA Y MICROFILAMENTO FINO CON MATERIALES DE LA CANTERA MEGAROK DE PICOAZA PARA RESISTENCIA DE F¨c 240 kg/cm2” La presente investigación tiene como objetivo realizar un análisis comparativo en el diseño de hormigones empleando fibras de polipropileno (fibrilada y microfilamento fino) con los agregados (finos y gruesos) de la cantera Megarok de la Parroquia Picoazá para obtener una resistencia nominal de F”c 240 kg/cm2. Para la construcción de los hormigones, primeramente se determinaron las propiedades físico-mecánicas de los agregados obtenidos, encontrándose que ellos presentan las características correctas encontrándose dentro de los rangos establecidos en la norma INEN 0862. Posterior a ello se determinó las dosificaciones necesarias de los agregados fino (1,90) y grueso (2,32), el cemento (1,00) y de agua (0,51), que componen la estructura del hormigón, estableciéndose que para la masa necesaria para elaborar los 6 hormigones propuestos son 8.023 kg de agua, 15.731 Kg de cemento, 29.825 Kg de arena y 36.420 Kg de ripio. Con los datos obtenidos se elaboraron los 6 cilindros de hormigones, de los cuales, 3 (15 kg c/u, contenían 5 g de fibras) los cuales servirán para desarrollar los ensayos para comprobar que su resistencia a compresión a los 7, 14 y 28 días presentaban los 240 Kg/cm2 requeridos, encontrándose en los resultados que ambos hormigones cumplían con la resistencia nominal requerida. Concluyendo que la utilización de las fibras de polipropileno agregada no influyen en la resistencia del hormigón final.
Description
"COMPARATIVE ANALYSIS IN CONCRETE DESIGNS USING FIBRILLED POLYPROPYLENE FIBERS AND FINE MICROFILMATION WITH MATERIALS OF THE MEGAROK QUARRY OF PICOAZA FOR RESISTANCE OF F¨C 240 kg / cm2" The objective of the present investigation is to perform a comparative analysis in the design of concrete using polypropylene fibers (fibrillated and fine microfilament) with the aggregates (fine and coarse) of the Megarok quarry of the Picoazá Parish to obtain a nominal resistance of F "c 240 kg / cm 2. For the construction of the concrete, the physical-mechanical properties of the aggregates obtained were first determined and found to have the correct characteristics within the ranges established in the INEN 0862 standard. Subsequently, the necessary dosages of the aggregates were determined (1.90) and thick (2.32), cement (1.00) and water (0.51), which compose the concrete structure, establishing that for the mass necessary to make the 6 concrete proposed are 8,023 kg of water, 15,731 kg of cement, 29,825 kg of sand and 36,420 kg of rubble. With the data obtained the 6 cylinders of concrete were elaborated, of which, 3 (15 kg each, containing 5 g of fibers) which will be used to develop the tests to verify that their resistance to compression at 7, 14 and 28 days had the required 240 kg / cm2, being found in the results that both concretes complied with the required nominal resistance. Concluding that the use of aggregated polypropylene fibers does not influence the strength of the final concrete.
"COMPARATIVE ANALYSIS IN CONCRETE DESIGNS USING FIBRILLED POLYPROPYLENE FIBERS AND FINE MICROFILMATION WITH MATERIALS OF THE MEGAROK QUARRY OF PICOAZA FOR RESISTANCE OF F¨C 240 kg / cm2" The objective of the present investigation is to perform a comparative analysis in the design of concrete using polypropylene fibers (fibrillated and fine microfilament) with the aggregates (fine and coarse) of the Megarok quarry of the Picoazá Parish to obtain a nominal resistance of F "c 240 kg / cm 2. For the construction of the concrete, the physical-mechanical properties of the aggregates obtained were first determined and found to have the correct characteristics within the ranges established in the INEN 0862 standard. Subsequently, the necessary dosages of the aggregates were determined (1.90) and thick (2.32), cement (1.00) and water (0.51), which compose the concrete structure, establishing that for the mass necessary to make the 6 concrete proposed are 8,023 kg of water, 15,731 kg of cement, 29,825 kg of sand and 36,420 kg of rubble. With the data obtained the 6 cylinders of concrete were elaborated, of which, 3 (15 kg each, containing 5 g of fibers) which will be used to develop the tests to verify that their resistance to compression at 7, 14 and 28 days had the required 240 kg / cm2, being found in the results that both concretes complied with the required nominal resistance. Concluding that the use of aggregated polypropylene fibers does not influence the strength of the final concrete.
Keywords
HORMIGONES, FIBRAS DE POLIPROPILENO
Citation
LOOR SANTOS RICHARD JESÚS.VERA SAAVEDRA YANDRY MICHAEL(2017).ANÁLISIS COMPARATIVO EN DISEÑOS DE HORMIGONES EMPLEANDO FIBRAS DE POLIPROPILENO FIBRILADA Y MICROFILAMENTO FINO CON MATERIALES DE LA CANTERA MEGAROK DE PICOAZA PARA RESISTENCIA DE F¨c 240 kg/cm2.FACULTAD DE CIENCIAS MATEMÁTICAS FÍSICAS Y QUÍMICAS.UNIVERSIDAD TÉCNICA DE MANABÍ.portoviejo. 68 p.
Enlace revista
Collections